    Description

    Runs 8 TO 12 HP 220 vac 3 phase motors on 220 vac single phase power. Uses include: Lathes, Mills, Grinders, Drills, Saws, Metal working and Woodworking equipment, Printing Machines and Equipment, Sewing Machines, Garbage Disposals, Food Processing Equipment, Meat Grinders, Dough Mixers, Food Blenders, Elevator Belts, and numerous other uses.
    The Sales Exchange, Inc York SC
    The Sales Exchange, Inc York SC
    Click image to enlarge
    Description
    ** STATIC PHASE CONVERTER **
    8 - 12 HP 220VAC - HEAVY DUTY
    LIST FOR 0.00
    Please read all information before ordering as the item cannot be returned
    Actual product resembles stock photo. Product is NEW.
    PHASE-A-MATIC™
    Static Phase Converter
    .
    Simple Installation
    Full 12 Month Warranty
    Immediate Delivery From Stock
    No More Changing Motors or
    Switch Gear
    FOR LIGHT TO MODERATE LOADS ONLY
    RUNS THREE-PHASE MOTORS FROM SINGLE-PHASE POWER AT
    2/3
    RATED HP
    *
    *
    Refers to wye-wound motors;
    delta
    -wound motors will run at
    50%
    rated HP. Delta-wound motors are very rare in the USA, occasionally being found on some imported equipment, and are particularly found on German and Italian machines.
    PHASE-A-MATIC™
    Static Phase Converters have been developed, tested, and thoroughly proven over a 46 year period demonstrating exceptionally high reliability and long life. These converters are the workhorse of many commercial uses and multitudes of home shop machines.
    LIFE EXPECTANCY:
    The Static Converter has been in use for approximately 46 years and has already proven itself to be extremely reliable when properly applied. Phase-A-Matic™ was recently able to purchase back the first one that was ever sold, and it is still working fine. It is reasonable to expect the converter to be in good working condition and service for 20 or 30 years or more. We continue to hear back from customers who have them still running their equipment faithfully after 20 years and more.
    Uses include:
    Lathes, Mills, Grinders, Drills, Saws, Metalworking and Woodworking Equipment, Printing Equipment, Sewing Machines, Garbage Disposals, Food Processing Equipment, Meat Grinders, Food Mixers and Blenders, Conveyer Belts, and numerous other uses.
    METHOD #1
    Using the PHASE-A-MATIC™ Static Converter
    only
    will produce approximately 2/3 normal HP.* This method is inexpensive, the most popular, provides excellent results on most machines tools and numerous other uses. Motor speed is not changed. Most two-speed motors, power feeds, coolant pumps, etc., will operate normally. Motor will instant reverse. There is nothing to change. All switch gear will work normally.
    *
    Refers to wye-wound motors;
    delta
    -wound motors will run at
    50%
    rated HP. Delta-wound motors are very rare in the USA, occasionally being found on some imported equipment, and are particularly found on German and Italian machines.
    METHOD #2
    FOR FULL OR CLOSE TO FULL HP
    ~~
    Configure as a rotary converter using Phase-A-Matic™ static unit
    ~~
    Full or close to full HP
    can usually be obtained by running a three-phase motor and PHASE-A-MATIC™ Static Converter combination as shown on the
    Installation Instructions
    shown below.
    When running unloaded, the windings of the motor function as a rotary transformer or generator while consuming very little extra power. The
    Idler Motor
    shown in method 2 below needs to be at least 50% larger than the largest motor that you want to run to accommodate the higher starting current. A good quality 3600 RPM, three phase wye-wound, 220V motor is the best choice. 1800 RPM motors can be used on applications not heavily loaded. Used three-phase motors are inexpensive and readily available.
    When using this method,
    it is possible to run multiple machines as long as the idler motor is large enough to handle the largest load it would ever have at any one time. For instant reversing of the load motor, as in rigid tapping, the idler motor must be a minimum of twice the HP rating of the load motor, and perhaps more.
    The Static Converter
    is sized to the HP of the idler motor, not the load motor(s).
    Static Converter Installation
    Method #1
    Caution:
    Read the following carefully before attempting installation.
    NOTE
    :
    It is best to mount the converter upright, not upside-down or side-ways as shown here.
    1.
    DO NOT
    connect 220V power or a ground or neutral to the center terminal of the Phase-A-Matic™ Static Converter as the resulting dead short will damage it instantly. The single-phase neutral wire is not required for operation of the converter. Properly ground all electrical equipment. Use a grounding clip to attach the ground wire to the conduit box. Resistive or single-phase loads must only be connected to lines A and C. This product is designed for indoor use only. Do not use in wet or damp locations. Do not mount on equipment with excessive vibration.
    2.
    The red indicator light
    should only come on when the motor is starting, and should go out once the motor has reached operating speed. The light should never stay on longer than 3-5 seconds since the converter could be damaged if it stays on longer. When testing the converter for the first few times after installation, keep your hand near the off switch of the machine, ready to turn it off, to prevent damage to the converter due to a wrong or loose connection.
    3.
    For machines with magnetic switch gear,
    DO NOT connect the Phase-A-Matic™ Static Converter until you identify which two wires operate the magnetics. To easily locate these two wires, connect 220V single-phase power to any 2 of the 3 wires on the machine, and press the start button. When the correct combination is found the magnetics will work. Connect these two wires to the outside terminals of the converter, lines A and C, and the third wire to the center terminal, line B. The magnetics should still work with the center terminal (line B) disconnected.
    4.
    The horsepower of the first motor to start,
    or Idler Motor if used, must fall within the minimum and maximum HP range on the converter. However, after the first motor, or Idler Motor, has started, motors below the minimum range may then be started and can usually be left running as the main motor is stopped and started.
    5.
    Always start
    a machine out of gear or in lowest spindle speed at initial hook-up to reduce load. The Phase-A-Matic™ Static Phase Converter has a built-in weak link which is designed to fail rapidly if hooked to a higher horsepower motor. On a lower horsepower motor the light could stay on after the motor is running, which would cause rapid failure of the converter, thus providing protection against possible motor damage.
    6.
    Fuses
    should not be used
    between the Phase-A-Matic™ Static Phase Converter and the motor. A blown fuse still leaves two lines to conduct which can damage the converter. Magnetic starters are preferred. If fuses are used, they should be placed on the single-phase lines L1 and L2.
    7.
    Using the Phase-A-Matic

    Static Phase Converter
    as in "Method Number 1" will produce approximately 2/3 of the rated horsepower.*
    *
    Refers to wye-wound motors;
    delta
    -wound motors will run at
    50%
    rated HP. Delta-wound motors are very rare in the USA, occasionally being found on some imported equipment, and are particularly found on German and Italian machines.
    8.
    Heavily loaded applications,
    such as compressors, blowers, water pumps, hydraulic pumps, etc., the motor pulley diameter must be reduced by 1/3, or a 50% larger motor must be fitted. Otherwise, "Method Number 2", the
    Idler Motor System
    , could be used. Or, use the Phase-A-Matic™
    Rotary Converter
    .
    9.
    Power may be left on
    the converter without the load applied. Current draw is approximately 8mA (.008 amp). The converter operates best when mounted vertically with the conduit box on top. Installation should be performed by a qualified electrician. Refer to local codes for proper wire sizing. Wires should be sized as appropriate for the motor's rated amperage. This unit is not recommended for use with phase-loss monitors.
    Method Number 2
    .
    Method #2
    IDLER MOTOR SYSTEM
    .
    Extra Precautions
    Isolation Switch Installation Diagram
    Full or close to full horsepower
    can usually be obtained by running a three phase motor and Phase-A-Matic™ Static Converter combination as shown in illustration below. The motor windings functions as a rotary transformer, or generator, and running unloaded, consume very little power. Used motors are inexpensive and readily available. A single machine or complete shop can be operated with greater flexibility using this method. The idler motor should be at least 50% larger than the largest motor you want to run to accommodate the higher starting current. A good quality 3450 RPM, wye-wound, 220V motor is the best choice. A 1725 RPM motor can be used on applications not heavily loaded. Lines A and C should always energize any magnetic switch gear or single phase loads. Always start the idler motor before applying the load.
    When using this method,
    it is possible to run multiple machines as long as the idler motor is large enough to handle the largest load it would ever have at any one time. For instant reversing of the load motor, as in rigid tapping, the idler motor must be a minimum of twice the HP rating of the load motor, and perhaps more.
    The Static Converter
    is sized to the HP of the idler motor, not the load motor(s).
    Extra Precautions
    For Idler Motor Systems
    Heavy starting loads
    may cause the output voltage on line B to drop sufficiently to cause the Static Converter to return to the starting mode. At this point, the converter's start circuit has the combined HP of the idler motor and the load motor. This will be indicated by the light on the converter coming on when the load motor is started. If the combined HP is greater than the converter's maximum HP range,
    DAMAGE TO THE CONVERTER MAY OCCUR
    . To prevent damage to the converter, place a heavy duty, single pole switch on line B, between the Phase-A-Matic™ Static Converter and the three pole switch. The switch must be in the "on" position before the idler motor is started, and turned to the "off" position after the light on the converter has gone out. This will prevent the converter from being damaged by an overload. Never turn the switch back to "on" while the idler motor is running. Doing so could cause damage to the converter. See following diagram.
    Method Number 2  Isolation Switch Installation
    Method Number 2
    Isolation Switch Installation
    Troubleshooting
    A.
    If the motor fails to start, and any of the following symptoms occur: clicking noises from the converter, light flashes on and off and motor just hums or buzzes, motor starts intermittently and  light goes off before motor reaches operating speed; this could indicate that either the motor is wired for 440 volts, or the Phase-A-Matic

    Static Phase Converter being used is too high in horsepower for the motor, and a smaller size converter should be tried. Also, check for proper connection of magnetics as per paragraph
    #3
    above, or improper overload heaters in magnetics.
    B.
    No voltage when measured across lines B and C without motor running: Normal.
    C.
    Converter occasionally hums when motor is turned off: Normal.
    D.
    Motor runs backwards: Reverse the
    three-phase
    lines A and C.
    Static Converter Application Notes
    1. WHAT TYPE OF CONVERTER
    SHOULD BE USED?
    The most important question is whether or not the motor is heavily loaded. You must keep in mind the fact that the motor will produce approximately 2/3 of its rated horsepower when running on the static converter. If the motor is loaded beyond that point, you must use our
    Rotary Converter
    ,
    or use method number 2 as explained in the
    Installation Instructions
    .
    Otherwise, you must unload the motor by reducing the motor pulley diameter by 1/3, or increase the motor horsepower size by 50% to accommodate the loss of power.
    NOTE:
    For the following outlined applications you
    MUST
    use a
    Rotary Converter:
    Battery Charger
    Plasma Cutter
    Some CNC Equipment
    EDM Machine
    Radar
    Transmitter
    (Radio & Television)
    Heating Elements
    Rectifier
    Variable Frequency Drive
    Laser
    Rheostat
    Welder
    2.
    REGULAR OR HEAVY DUTY
    SERIES?
    Next you must determine whether to use a Regular Duty or Heavy Duty converter. Keep in mind you can always use a Heavy Duty converter in place of a Regular Duty one. A Heavy Duty converter will not provide greater
    horsepower
    . However, there are some static converter applications for which you should always use the Heavy Duty series.
    These are:
    1.
    Frequent starting (more than once a minute).
    2.
    Instant reversing.
    3.
    Unattended equipment, such as air compressors.
    4.
    Long, heavy starting cycles, such as lathes without a clutch, flywheel driven equipment, etc.
    5.
    If jogging is required.
    6.
    If there is a chance of the motor being stalled during use (woodworking equipment, etc.).
    3.
    WHAT HORSEPOWER RANGE
    CONVERTER SHOULD BE USED?
    Next, you must find the proper horsepower range for the application. The largest motor on the machine, or idler motor if used, must fall within the minimum and maximum ranges of the converter. Two speed motors are usually dual horsepower. For example, a 3 horsepower 3600 RPM motor is 1-1/2 horsepower at 1800 RPM. You should select a converter with a minimum and maximum range, which will accommodate both horsepower ratings. However, with Taiwanese and Chinese motors, the larger horsepower should be at the lower range of the converter whether it is a two speed motor or not. For example, for a 5 horsepower Taiwanese motor you should use a 4-8 horsepower range converter, even if it is a two speed motor with 2-1/2 horsepower on the low speed. This is because Taiwanese and Chinese motors draw more amperage during start than do domestic motors and therefore require a slightly larger converter than would normally be used. A larger size converter will not provide greater horsepower.
    A Few
    Additional Items to Remember:
    1.
    The first motor to start on the converter must fall within the minimum and maximum horsepower range on the converter. However, after the first motor has started, motors below the minimum range may be started and can usually be left running as the main motor is stopped and started.
    2.
    Do not add the horsepower of the power feed, coolant pump, or other accessory motors when sizing a converter. The only time you would add the horsepower of two or more motors together would be if they always start at exactly the same time.
    3.
    A larger size converter or a Heavy Duty series converter will not produce greater horsepower than a Regular Duty converter.
    4.
    Heavily loaded equipment usually consists of equipment with pumps, blowers, fans, compressors, etc.
    Payment
    Winning bidder has 24 hours to make contact with seller. Payments must be made within 2 days of the auction end. The winning bidder can pick up the item from the seller at no extra cost. If shipping is needed, the buyer pays the cost of shipping and handling.
    Shipping
    Shipping charges are the responsibility of the purchaser.  We try to ship your item the safest and least expensive way we can.  We will also use your shipper if you would like. To obtain a quote for shipping by common carrier, please message me your city, state and zip code and whether you are a residential or commercial address.  I also need to know if you need a lift gate or dock delivery.  I will send you an estimate asap. There will be an additional skidding fee if shipped by common carrier.
    Terms of Sale
    All sales are final.  No returns are accepted unless otherwise stated.
    About Us
    The Sales Exchange, Inc. History and Philosophy of Operation
    From its beginning 30 years ago, The Sales Exchange, Inc. has grown into a leading supplier all types of equipment for commercial and industrial applications.
    Over the years, TSE has earned it's reputation through proven reliability, fast service, and the ability to find whatever a customer is in need of. TSE also carries an extensive inventory of used and reconditioned equipment from many different divisions of the textile industries.
    We now represent many other equipment manufacturers that specialize in the electronics, robotics, power transmission, and the material handling industry.  If you dont see it on our web site or in our EBay store, message us so we can help you locate it.
    Thanks in advance for the opportunity to serve you.
    Charlie
    Contact Us
    Feel free to message Charlie anytime.
    Pictures sell!
    Auctiva offers Free Image Hosting and Editing.
    300+
    Listing Templates!
    Auctiva gets you noticed!
    The complete eBay Selling Solution.
    Track Page Views With
    Auctiva's FREE Counter